Advanced Wide Angle Geometry (WAG™) optics provide high x-ray flux, which leads to optimal excitation conditions.
Through the use of secondary targets with computer-varied voltages and emission currents, the EX-6600 provides polarized excitation energy, increased signal-to-noise ratio, superior sensitivity and selective excitation of elements.
The near absence of background radiation produces extremely low detection limits.
The Multi-Channel Acquisition resolution provides superior peak-to-background ratio for improved detector response.



Features

Some unique features of the EX-6600:
- Close-coupled optics in the secondary target mode allow for greater flux and superior sensitivity
- Eight customizable filters and eight secondary targets
- To further enhance repeatability and reliability, the entire sampling chamber and analysis area are mechanically isolated and vibrationally dampened.
- With our proprietary end window tube design, fewer secondary electrons impinge on the Be window.
- The ultra-thin Be window provides superior performance for the low Z elements.

Specifications

Excitation type Direct with filters and secondary target
Detector Type New generation Si(Li) PIN Diode with Light Element Option window
Detector Cooling LN2
Coolant Sensor Reports levels from 0-100% in 1% increments and includes a low LN2 alarm and automatic bias cut-off warning
Dewar Capacity 31 litres - typical refill cycle of more than 14 days
Detector Resolution 140eV +/-5eV at 5,9keV

Detector Window Thickness

Custom designed
Tube Type

End window - front anode
Rh-anode standard (optional Mo, W, Pt, Cr)

Maximum tube potential 60 kV (3~60 kV in 1 kV increments)
Maximum tube power 400 Watts
Elements analysed
Na-U
Number of tube filters 8 software selectable filters; open, Cl, Ti, Fe, Cu, Mo, Rh, Sn
Number of Secondary Targets 8 (Mg, Si, Ti, Fe, Ge, Mo, Sn, Gd)
Standard autosampler 10-position; samples up to 47 mm in diameter
Type of Analysis Qualitative and Quantitative
Computer Integrated Data System
Software nEXt Windows based analytical software
Power requirements 115 or 230 V AC (1,2 or 0,6A respectively), 50/60Hz
Dimensions 84×57×102 cm (unpacked)
85x100x130 cm (packed)
Weight 230 kg(gr. weight) / 180 kg (net.weight)
Data Processing and Storage Advanced analog processor with gated baseline restorer, digital zero correction and software selectable time constants. 16-bit successive approximation analog to digital converter with integral 2048 channel multichannel analyser and digital peak detector.
Options Thermoelectrically cooled LN2--Free Detector
Sample Spinner
 
alt

This specification can be changed without prior notice