Ultrasonic homogenizer (sonicators) SONIC series are multifunctional and universal instruments that use the power of ultrasonic disintegration of cells. With these devices can be successfully homogenised cells of many species of animals, plants and viruses, in a short time to give homogeneous emulsions. Laboratory homogenizers this type are widely used in biochemistry, chemistry, medicine, physics, zoology, and others. Digital ultrasonic homogenizers Sonic eqquiped with chamber and a temperature sensor intended for homogenizing in a laboratory.
Peristaltic pump BT-M series providing adjustable flow rates for common laboratory applications. The speed can be adjusted manually or automatically through external control. Laboratory flow rate peristaltic pump characterized by quick operation speed, stable work and high precise transfer. Peristaltic pump BT-M series are equipped in 3-digit LED to displays current rotating speed and rotary encoded switch control speed.
Combined Hydrogen/Air gas generator LC-H2, ND-H2, PAR-H2-ZA can provide both hydrogen gas and zero grade air to FID detectors on
gas chromatographs. Hydrogen gas is produced from deionised water using a proton exchange membrane technology. Zero air is produced by purifying compressed air sourced from the air network to a total hydrocarbon concentration of < 0.05 ppm (measured as methane).
The H2/AIR station combine the hydrogen serie: LC-H2 and Zero air serie ZA (FID-H2/AIR), ND-H2 and Zero air serie ZA, PAR-H2 and Zero air serie ZA generators in one unit. Units are complete systems with highly reliable components engineered for easy installation, operation, and long term performance.
Applications: Ionization flame detector (FID), Fuel gas and air Flame Ionization Detectors, Flame Photometric Detectors, Total Hydrocarbon Analyzers.
Improved chromatograph result: The reduction of hydrocarbons on zero air part, including methane to <0.05 ppm decreases the background noise level and gives the baseline much better stability, considerably increasing detector sensitivity and ensuring precise analytical results. The use of hydrogen as a carrier gas allows lower temperature elution, thus extending the life of the chromatograph column. Hydrogen as a carrier gas is faster and more sensitive than the more-expensive helium. Run time savings of 25% to 35% without a decline in resolution.
Technical specifications is for combined LC-H2 and Zero air serie ZA (FID-H2/AIR).
Nitrogen generators ALIZE series are some of best designed PSA nitrogen gas generators available. Utilizing the reliable and efficient PSA technique of separating nitrogen and oxygen is used to produce high quality nitrogen gas at various flows and purities. A constant, uninterrupted gas supply of guaranteed purity eliminates interruptions of analyses to change cylinders and reduces the amount of instrument re-calibrations required, pure nitrogen gas produced as standard. The generator is controlled using the latest in HMI touch screen technology to display the process in real time, inlet/outlet pressures and oxygen level ( optional).
Application: GC, ELSD / CORONA, ICP, COT, Sample evaporation
Available models gas generators ALIZE: Catalyst module for hydrocarbons level< 0.05ppm (ZERO NITROGEN- serie Z-ALIZE), generators with integral oil free air compressor (ALIZE1/1, ALIZE 3/1, Z-ALIZE 1/1, Z-ALIZE 3/1 series).
Hydrogen generators PAR-H2 Series are high purity hydrogen generator with programmable auto regeneration cartridge. PAR-H2 series gas generator produced hydrogen with purity > 99.9999% with different flow rate: from 120 cc/min to 650 cc/min. Laboratory gas generator PAR-H2 Series use a single column dryer with programmable automatic regeneration via an integrated clever calendar. Gas generators are equipped with LCD touch screen to show real time outlet pressure, water quality, water level, autodiagnostics with alarms and communication ports: RS-232, RS-485, USB, LAN. The exclusive parallel working mode option allows up to 10 units to be connected, producing flow-rates of up to 9 L/min for PAR-H2 series.
The PAR-H2 series generators are ideal for: Ionization flame detector (FID), carrier gas for GC e GC-MS, collisions on ICP-MS, small fuel-cell cylinder refills
Hydrogen generator ND-H2 Series use the latest polymer electrolyte membrane (PEM) technology to produce pure hydrogen. The unit use a desiccant cartridge which needs to be refilled or replaced when saturated. The advantage of ND-H2 series gas generator is the possibility of applying high delivery pressure- up to 10 bar and the production of high purity hydrogen (> 99.9995%). Gas generators are equipped with LCD touch screen, can control real time outlet pressure, water quality, water level, autodiagnostics with alarms.
Gas generators can be installed in the laboratory, on or under a bench, eliminating the need for long gas lines from cylinders secured elsewhere. Capabilities allowing to work in parallel mode (optional).
The ND-H2 series generators are ideal for: ionization flame detector (FID), carrier gas for GC e GC-MS, collisions on ICP-MS, small fuel-cell cylinder refills.
Hydrogen generator LC-H2 Series are compact gas generators use a desiccant cartridge which can be refill or replaced by a new one. The LC-H2 hydrogen generators use the latest polymer electrolyte membrane (PEM) technology to produce pure hydrogen. LC-H2 models available: 100, 140, 180 cc/min and H2 purity:> 99.9995%. The LC-H2 series generators are ideal for: Ionization flame detector (FID), Small fuel-cell cylinder refills.
THICK 8000 spectrometer is a high performance spectrometer designed for rapid and non-destructive analysis of coating thickness and elemental composition. Allow measurement of single or multilayer coatings (gold, silver, copper, nickel, tin and zinc). It can be widely used in research of content of gold platinum, silver and other precious metals in the jewelry industry and research of coatings. Conduct analyzes in the plating industry, both the composition and thickness of electroplated coatings and plating bath composition.
THICK 8000 analyzer provides the best illumination structure of the sample, by using the mobile platform (provides movement in three dimensions), and the laser positioning system it becomes possible to test point by point the coating thickness and elemental composition of the samples with large sizes. It is equipped with a SDD detector and micro-collimators with the possibility of automatic switchover.
THICK XRF spectrometer 800A is designed to analyze the thickness and composition of galvanic coatings specially designed to permit convenient multi-point analysis of the products in the plating industry, jewelry and electronics. THICK 800A spectrometer can be used to study the content of gold, platinum, silver and other precious metals in the jewelry industry and research of coatings. Also conducts analysis in the plating industry, both the composition and thickness of electroplated coatings and plating bath composition. The analyzer provides the measurement of up to 24 elements or five layers of coatings. It comes with software that contains elements of the fundamental parameter method (FP).
XRF analyzer THICK 800A is equipped with an overhead light source and a collimator with a small cross-section of for precise localization of the measuring point. 2D mobile platform, dual laser tracker and a high-resolution camera, ensure precise positioning of the measuring point.
ECOSYS is a fully portable quadrupole mass spectrometer. Using modern technology in the field of QMS comprising a full laboratory instrumentation obtained device with excellent performance and flexibility. Thanks to miniaturization achieved small size of the system, while maintaining a very high functional capacity. ECOSYS system is designed - inter alia - to work in the field, it is equipped with a battery that allows continuous work up to 8 hours; appropriate, easy-to-use software system that allows to perform a full quantitative analysis and monitoring of up to 64 species in real time.
ECOSYS The mass spectrometer is based on the EIS technology (Enclosed Ion Source), which greatly increases the scope of the received signal and can increase the sensitivity of measurement (detection at the level of ppm). ECOSYS has an option to evaluate the data based on the spectra library NIST (National Institute of Standards and Technology) allows the user to identify unknown compounds.